EasyManuals Logo

Interlogix Advisor Advanced ATS 000A Series User Manual

Interlogix Advisor Advanced ATS 000A Series
272 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #214 background imageLoading...
Page #214 background image
204 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Table 39: Camera events and reporting codes
Event type
Activated by zone type [1]
SIA code [2]
Burglar alarm
1. Alarm, 2. Entry/Exit 1, 3. Access, 6. 24H, 13. Fire door,
16. Key box, 18. Entry/Exit 2
BA
Fire alarm
4. Fire
FA
Panic alarm
5. Panic
PA
Medical alarm
10. Medical
MA
Tamper alarm
7. Tamper
TA
Fault
11. Technical, 12. Transmission path fault, 14. Aux mains
fault, 15. Aux batt fault
UA
Custom type 1
Not allowed [3]
Selectable [4]
Custom type 2
Not allowed [3]
Selectable [4]
[1] Zones of particular types do not activate camera. These are 8. Exit terminator, 9. Keyswitch,
17. Eng. reset. When an assigned zone is one of the listed types, it is ignored when active.
[2] If the camera has been activated by a standard reporting event, another event caused by
camera activation does not occur. Detailed codes and subevent values are described in
Reporting codes used in Advisor Advancedon page 223.
[3] Custom type events can only be activated by condition filters.
[4] See “4.3.n.3.m.3 Report ason page 111 for details.
Each of these types can be configured in 2.2.2.n.4.9.1 Pic settingson page 79.
Depending on camera event type, the camera can be programmed to take a
single picture or a series of pictures, in low or high resolutions.
How to program a camera:
1. Program the wireless PIR camera expander. See “Deviceson page 66 for
more details.
2. Program a wireless PIR camera as a wireless PIR detector. See “Wireless
device programmingon page 197 for more details.
If the detector is programmed successfully, the appropriate camera is created
automatically. The created camera number is equal to the zone number of the
wireless PIR detector.
3. Program the camera options. See “4.3 Camerason page 110.
4. Assign zones to the camera. Choose up to four zones. The camera is useful if
its field of view covers these zones or possible burglar escape paths from
there. See “4.3.n.2 Pics by zoneon page 110.
By default, the first assigned zone is the zone of the wireless detector built in
the configured wireless PIR camera.
5. If necessary, program conditional event filters that activate the camera. See
4.3 Camerason page 110 for details.
6. If necessary, program reporting events that activate the camera. See “4.3
Camerason page 110 for details.

Table of Contents

Questions and Answers: