Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 27
Standard onboard outputs
S1, S2
High current electronic output, rating: 1 A at 13.8 V
S3, S4, S5 [1]
Low current electronic output, rating: 50 mA at 13.8 V
[1] Maximum cable length for low current output connection may not exceed 30 m. For longer
distances, use relay output expansion (for example, ATS624 four-relay expander).
Environmental
Operating temperature
0 to +40°C
Tested temperature according
EN 50131
10 to +55°C
Humidity
95% noncondensing
IP protection grade
IP31
Colour
Beige
Dimensions
See “List of panel variantson page vi
EN 50131 grade and class
ATSx000A(-IP): Grade 2, Class II
Safety class
Class I
Enclosure type
Enclosure (meets UL94V-0)
Overvoltage category
Category II
Maximum altitude, or minimum air
pressure
2000 m above mean sea level
Fuses
Battery
2 A, resettable
12 V aux
1 A, resettable
System databus
1 A, resettable
Siren 1, high current output S1
1 A, resettable
Siren 2, high current output S2
1 A, resettable
Mains, mains fuse:
ATS1000A(-IP)
315 mA, fast 20x5
ATS2000A(-IP)
630 mA, fast 20x5
Note: Mains fuse is part of the mains terminal block.
WARNING: Before removing the mains fuse, mains power must be disconnected
(see Mains power connectionon page 8).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Advisor Advanced ATS 000A Series and is the answer not in the manual?

Interlogix Advisor Advanced ATS 000A Series Specifications

General IconGeneral
BrandInterlogix
ModelAdvisor Advanced ATS 000A Series
CategoryControl Panel
LanguageEnglish

Related product manuals