Advisor Advanced ATSx000A(-IP) Installation and Programming Manual  53 
1.2.5.2.6 Siren tamper 
 
If the Siren tamper option is set to Yes, the tamper alarms from sirens assigned 
to this area also have to be tested. 
1.2.5.2.7 Frequency 
 
The Frequency setting defines, how often the user is requested to perform the 
user walk test prior to setting an area. The following options are available: 
Table 16: Walk test frequency 
User walk test is not requested 
User is asked to perform the walk test prior to each set 
User is asked to perform the walk test prior to the first set each day 
User is asked to perform the walk test prior to the first set each week 
User is asked to perform the walk test prior to the first set each month 
Note: For walk test purposes Advisor Advanced stores information on any zone 
activation for 4 hours. Therefore if the zone was activated during the last 4 hours 
before walk test, it is not included into the list of zones required to test. If each 
walk test zone was activated during this time, the walk test is not requested. 
1.2.5.2.8 Need to set 
 
If Need to set option is set to On, the requested user walk test is obligatory. The 
area cannot be set until the walk test is passed. 
1.2.5.2.9 Reduced walk 
 
Reduced walk test period is a time period before reduced walk test start, in which 
particular zone activation excludes this zone from the list of zones being tested. 
The following options are available: 
•  4h: Reduced walk test only includes zones that were not active during last 
4 hours.  
•  Set2set: Reduced walk test only includes zones that were not active since the 
last set.  
See “1.2.5.1 Walk test start” on page 51 for more details on reduced walk test.