54 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
1.2.5.3 Single zone WT
Before walk test starts, you are asked if the reporting to central stations must be
enabled (see “1.2.5.1 Walk test start” on page 51 for details).
Select the input location first (panel, internal or external expander). Then enter
the (physical) input number on this location.
Proceed with walk test for this particular zone the same way as for all zones in a
standard walk test. See “1.2.5.1 Walk test start” on page 51.
1.2.5.4 Special WT mode
A special walk test mode allows verification of the whole alarm system
functionality. In this mode, a service engineer or a guard must perform as many
actions on the operating alarm system as possible. This may include set and
unset, entry and exit, activating all detectors and tampers. The system operates
as usual, sending all alarm and tamper events to the central station, except none
of system sirens is active.
This allows the central station operator to review all received alarms and verify if
appropriate system functions are working properly.
1.2.6 Test call opts
The Test call menu allows you to define the automatic test call interval, and to
perform a test call on demand.
1.2.6.n Select central station
1>Test call mode
2 Period
Select central station to configure test call options.
1.2.6.n.1 Test call mode
Choose one of the following modes for the automatic test call.
• Off: Automatic test call is disabled.
• Period: Automatic test call recurs at defined intervals.
• Time: Automatic test call occurs every day at a specified time.