Chapter 4: Menu reference
102 CDC4 Door Controller Installation and Programming Manual
IN reader options
Each door can have up to six readers in any combination of IN readers and OUT
readers.
A reader is defined as an IN reader if its Door side field is set to IN reader when it
is added using the Door reader dialog (accessed from the Readers tab for the
door). Similarly, a reader is defined as an OUT reader if its Door side field is set
to OUT reader when it is added using the Door reader dialog.
Card and PIN
Select this option to require that both a card and a PIN must be used to unlock
the door via any of the IN readers. If not selected, then either a card or a PIN will
unlock the door via any of the IN readers.
See also “Low Security Scheduleon page 101.
No PIN if Low Security
Select this option to require that only a card must be used to unlock the door via
any of the IN readers during the low security schedule (see the “Low Security
Schedule” section on page 101). If not selected, then both a card and a PIN must
be used to unlock the door via any of the IN readers during the low security
schedule.
Deny region 1 users
Select this option to prevent users who are currently recorded as being off-site
(i.e. in region 1) from unlocking this door via any of the IN readers.
See the “Regionson page 54 for more information about regions.
Two-badge
When selected, two different users must present their card and/or PINs in
succession in order to unlock the door via any of the IN readers.
The presentation of card and/or PIN must occur within the two-badge time (see
the “Dual Badge Timeon page 99).
Once the two valid card and/or PINs have been presented to the reader, a
60 second timer starts, which allows the second user to perform functions such
as locking the door, or alarm control.
For example, if the IN alarm control for the door is set to Alarm control on 1st
badge, then the second user can present their card to disarm areas. See the “IN
alarm control” section on page 110.
Similarly, if 2 badge unlock, 1 badge re-lock is configured for the door, then the
second user can present their card to lock the door. See the “Two badge unlock,
one badge relock” section on page 103.
OUT reader options
The options for IN readers can also be applied to OUT readers.