Chapter 2: System functions
72 CDC4 Door Controller Installation and Programming Manual
Random lockout time
When the “Door random bit” event triggers on a door controller door (which can
occur if the door Random setting is non-zero), then there is a new setting which
locks out the door for a specified amount of time, called Random lockout time.
The lockout time can also be specified as indefinite. During this time, the door
can only be opened by users with the “Privileged” flag; the door cannot be
opened by any other users.
Any LCD RAS attached to the door will display “Locked Out”.
Note: Users with the “Privileged” flag cannot cause a door lockout.
A door random lockout time can be programmed in Downloader on the Access
tab of the Doors form. See the “Random lockout time” section on page 101.