Chapter 4: Menu reference
88 CDC4 Door Controller Installation and Programming Manual
Programming mapped outputs
You can configure its settings in the Panel data window > Outputs list.
Assigned RASs tab
Keypads and readers attached to one of the door controller local buses must be
assigned to CDC4 on the Assigned RAS tab of the Expander form.
Select the appropriate keypad and click Browse “...” to open the Assigned RAS
form.
The following settings are available.
Name
When a RAS is created, it is given the default name “RAS <n>”, where <n> is the
RAS number. Enter this menu to edit the current name.
RAS type
This read-only field shows the format used by the bus for the selected RAS. See
the “Bus options” section on page 84.
RAS model
If the Bus format field is set to ATS, then the RAS model can be selected from
the following:
ATS1190/1192: ATS smart card reader
ATS1197: ATS smart card reader with keypad
ATS1160N/ATS1161N: ATS Mifare DESFire & EV1 reader (with keypad)
ATS1151: ATS keypad with 3 LED
ATS1156: ATS magstripe card reader with keypad
ATS1155: ATS heavy-duty keypad
ATS1170: ATS Wiegand/reader interface
ATS118x: ATS smart card readers
Aperio EAC
If the Bus format for the bus is set to Aperio, then enter the Aperio EAC
(Electronic Access Control) number in this field. Values can range from 1 to 255.
Poll
Set the option to On to poll the device.
Remove
Click Remove to delete the selected device.