Chapter 4: Menu reference
CDC4 Door Controller Installation and Programming Manual 111
Low Security when IN areas disarmed
If the option is set to Yes, the user authorization mode changes from Card and
PIN to Card or PIN after the state of door IN alarm control areas is changed to
unset.
Lock door when IN areas armed
If the option is set to Yes, the door is locked automatically after the state of door
IN alarm control areas is changed to set. Note: This option influences only the
setting process. Manual or calendar action can unlock the door. Changing this
option will not change the door state on the configuration update.
Unlock door when IN areas disarmed
If the option is set to Yes, the door is unlocked automatically after the state of
door IN alarm control areas is changed to unset. Note: This option influences
only the unsetting process. Manual or calendar action can unlock the door.
Changing this option will not change the door state on the configuration update.
IN alarm control levels
This field shows a list of alarm control levels for the door IN readers, as
configured on the Readers tab for the door. Alarm control levels are defined on
the door Alarm control levels tab (see “Alarm control level tab” on page 95).
Open the list to assign alarm control levels to the door IN readers. In the dialog,
select the required alarm control levels.
OUT alarm control levels
This field shows a list of alarm control levels for the door OUT readers, as
configured on the Readers tab for the door. Alarm control levels are defined on
the door Alarm control levels tab (see “Alarm control level tab” on page 95).
Open the list to assign alarm control levels to the door OUT readers. In the
dialog, select the required alarm control levels.