EasyManua.ls Logo

Interlogix CDC4 - Page 33

Interlogix CDC4
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 1: Installation
CDC4 Door Controller Installation and Programming Manual 27
Devices can be connected to CDC4 via the 4-pin RS-485 terminals for bus 1
(Figure 12 on page 13, item 19) or bus 2 (Figure 12, item 18).
Alternatively, devices can be connected to Bus 1 via the 4-pin plug-in RS-485
sockets (Figure 2 on page 7, items 17 and 20). The sockets are for easy
connection to the expander boards that support the connection such as the CDC-
2DWIF Dual Wiegand Interface.
Using the plug-in Bus 1 sockets
To easily connect an expander board to Bus 1, connect a 4-way RS-485 cable
(supplied with the expander board) to one of the 4-pin plug-in RS-485 cable
sockets (Figure 2 on page 7, items 17 and 20).
Refer to Figure 4 on page 12 for example connections of 4-way RS-485 cables
from a NAC to an expander board (items B and D).
Figure 15: Example CDC4 to CDC-2DWIF cable connections for RS-485 and lock power
A, C: 2-wire lock power cable
B, D: 4-wire RS-485 cable
Using the data bus terminals
An example connection of a reader to one of the local buses is shown in
Figure 16 on page 28.
CDC4
CDC-2DWIF
CDC-2DWIF
A B
C D
A
B
C
D
A
B
C
D

Table of Contents