Chapter 2: System functions
CDC4 Door Controller Installation and Programming Manual 55
The system does not allow the normal user to stay in the HSR without HSU
inside, so the last high security user will not be permitted to leave the high
security area if there are normal users inside.
Note: Privileged users are still allowed to access the regions where the limits for
users or high security users are exceeded. See also “Userson page 112.
Set HSU options in “Expander devices > Region/HSU Configuration tabon page
92.
High security user requires the Access user type option to be set to High Security
User. See also “Userson page 112.
Alarm control by region
If the alarm control by region is enabled, the last user leaving the region assigned
to door automatically sets the area, and the first user entering the region unsets
it.
To configure the functionality, do the following:
Set the following options in Expander > Region/HSU Configuration tab:
- Set the region number for alarm control in “Regionon page 92.
- Enable “Alarm control by regionon page 94.
- If necessary, enable “Delayed Armingon page 94. If enabled, the keypad
will prompt to activate a delay for the set. See Advisor Advanced ATSx500A
Installation and Programming Manual for more details on the delayed set.
- Set the required alarm control levels in Alarm Levels 1..6on page 94.
These levels define the areas that should be set or unset.
Set the following options in Doors > Shunt/RTE/AntiPassback tab:
- Set the region being set in In regionon page 106.
- Set Out regionon page 106 to the number of the region that users are
moved to after the area is set.
Set the following options in Doors > Alarm control tab:
- Set the IN alarm controlon page 110 to Alarm control via region count.
- Set the “OUT alarm controlon page 110 to Alarm control via region count.