Chapter 2: System functions
68 CDC4 Door Controller Installation and Programming Manual
Door controllers may use the first 12 addresses on the Advisor Advanced system
bus. Table 9 below lists the address of CDC4 (set via the CDC4 DIP switches),
the expander number that the CDC4 controller is polled as, and the ranges of
Advisor Advanced input and output numbers.
Table 9: Advisor Advanced inputs and outputs per expander address
Address
Polled as
Advisor Advanced inputs
Advisor Advanced outputs
1
Expander 1
17 to 48
17 to 48
2
Expander 2
49 to 80
49 to 80
3
Expander 3
81 to 112
81 to 112
4
Expander 4
113 to 144
113 to 144
5
Expander 5
145 to 176
145 to 176
6
Expander 6
177 to 208
177 to 208
7
Expander 7
209 to 240
209 to 240
8
Expander 8
241 to 272
241 to 272
9
Expander 9
273 to 304
273 to 304
10
Expander 10
305 to 336
305 to 336
11
Expander 11
337 to 368
337 to 368
12
Expander 12
369 to 496
369 to 400
In order for Advisor Advanced to utilise the mapped inputs and outputs, you must
also program the Advisor Advanced input and outputs. See the ā€œProgramming
mapped inputs and outputsā€ section on page 87 for instructions.