Intermec EasyCoder 501 Service Manual Ed. 7
116
Chapter 15 Scaleable Fonts Kit
15.2 Installation
To install a Scaleable Fonts Kit, proceed as follows:
Switch off the power, and disconnect the power cord.
Open up the electronics compartment by removing the eight
#T10 Torx screws that hold the left-hand cover.
Check that there are no jumpers tted in the right-hand posi-
tion on P-100, P-101, and P-102 on the CPU board. Such
jumpers indicate that the printer is tted with Flash Memory
packages, which excludes the installation of the Scaleable Fonts
Kit. No jumpers tted, or jumpers tted in the left-hand posi-
tion, is OK
1
.
Remove the existing GAL circuit on IC-700 on the CPU board
and replace it with the smallest of the circuits included in the
kit. The small semicircular mark must face upward.
Fit the EPROM package marked # 5 in socket IC-104, and
the EPROM package marked # 6 in socket IC-105. In both
cases, the semicircular mark must face upward.
Inspect the circuits you have tted for bent legs. If necessary,
remove the circuit and re t it.
Put back the left-hand cover, connect the power cord, and
switch on the power.
POWER ON
040700.10
040700.10
FLASHEPROM
232
CL
422
P-102 P-100 P-101
IC-700
IC-104
IC-105
+-
CHECK JUMPERS HERE!
GAL
EPROM's
# 5
# 6
Screws (4x)
Cover
Screws (4x)
1
/. Refer to Chapter 17, “CPU
Board” for more information
on the relation between jump-
ers on P-100 to P-102 and the
type and size of memory pack-
ages on IC-100 to IC-105.