EasyManua.ls Logo

Intermec EasyCoder 501 - Description; Easycoder 501 S

Intermec EasyCoder 501
227 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intermec EasyCoder 501 – Service Manual Ed. 7
192
Chapter 25
25. Test Mode
25.1 Description
The Test Mode comes in two versions;
A limited test mode for EasyCoder 501 S.
A full test mode for EasyCoder 501 E, EasyCoder 501 SA, and
EasyCoder 501 LL.
You can enter the full test mode on an EasyCoder 501 S if a special
Service GAL circuit is fi tted on IC-700 on the CPU board and a
Service Keyboard is connected to P-2, replacing the existing key-
board.
The Service GAL and the Service Keyboard come as a kit, part
number 1-501660-00. The kit is recommended for service of Easy-
Coder 501 S printers without Intermec Shell installed (customized
applications) and facilitates LSS adjustment and communication
reset.
The limited Test Mode for EasyCoder 501 S allows a series of test
labels to be printed (see Chapter 24.1). Enter the mode as follows
(also see diagram on next page):
Switch off the printer.
Lift the printhead.
Press the <Print> key and keep pressing it.
Switch on the power. Keep on pressing <Print>.
Wait a few moments until this message appears in the display:
PRINT TEST LABEL
Lower head!
Release the <Print> key and lower the printhead to Print
position.
This message appears:
<PRINT> = PRINT
Lift head = EXIT
Press the <Print> key. Each time the key is pressed, a new test
label is printed in a loop.
To exit, lift the printhead and press <Print>.
Switch off the power.
Restart the printer as usual.
25.2 EasyCoder 501 S