Chapter 23 Industrial Interface Board
Pin "uart3:" Remarks Pin In/Out connector Remarks
DB-25 female DB-15 female
1 GNDC Cable shield 1 OUT 201 See example on next page
2 TXDB Transmitted data from printer 2 OUT 201
3 RXDB Received data to printer 3 OUT 202
4 RTSB RTS from printer 4 OUT 202
5 CTSB CTS to printer 5 OUT 203
6 DRSB DSR to printer 6 OUT 203
7 GNDI Signal ground 7 OUT 204
8 not used 8 OUT 204
9 not used 9 IN 101 See example on next page
10 not used 10 IN 101
11 not used 11 IN 102
12 not used 12 IN 102
13 not used 13 IN 103
14 not used 14 IN 104
15 not used 15 IN 103/104
16 +5VEXT + 5V max 200 mA*
17 not used
18 not used
19 not used
20 DTRB DTR permanently high
22 not used
23 not used
24 not used
25 not used
*/. If strap fi tted on P-1
23.3 Connector Confi g-
uration
OUT signals are controlled using
PORTOUT (<nexp>) ON|OFF statements.
IN and OUT signals are read using
PORTIN (<nexp>) functions.
Also see Intermec Fingerprint v6.14, Reference Manual.
"uart3:" is a DB-25pin female connector.
The In/Out connector is a DB-15pin female connector.
The mounting holes are connected to chassis ground.

Table of Contents