149Intermec EasyCoder 501 Service Manual Ed. 7
Chapter 18 "uart1:"
232
CL
422
"UART1:"
P202
IC-200
P203
3 2 1
P200
+-
P-203
(external +5V)
P-202
(Interface select)
IC-200
(RS-232 circuit)
P-200
(DTR/RTS select)
RS-232 (V24) is the most common interface for serial commu-
nication with computers over short distances. The transmission
can only take place between one transmitter and one receiver.
The most simple form of two-way communication only requires a
3-wire cable. The maximum transmission distance is about 10 to
15 metres (33 to 49 ft.) and the maximum transmission speed is
19,200 baud (38,400 on optional interface boards).
RS-232 circuit must be tted on IC-200 ( tted as standard).
Jumper must be tted on uppermost position of P-202.
RS-422 circuit on IC-207, optocouplers on IC-205 and IC-206
(optional) and straps on P-204 to P-209 are of no consequence.
The following hardware straps can be tted:
P-200 DTR-signal:
Pin 12 DTR indicates printer turned on.
Pin 23 A copy of the ow signal RTS is produced.
P-203 External 5 Volt
1
:
Jumper tted connects +5V to pin 16.
Caution!
Max 200 mA. Be careful not to enable the external 5V unin-
tentionally, which may cause harm to the terminal, PC, or
other device connected to this port!
18.2 RS-232 (V24)

Table of Contents