EasyManua.ls Logo

Intermec EasyCoder 501 - Connector Confi Guration

Intermec EasyCoder 501
227 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
173Intermec EasyCoder 501 Service Manual Ed. 7
Chapter 22 Parallel Interface Board
The connector is standard female 36-pin Centronics type. The
mounting holes are connected to chassis ground.
Note:
The PE signal (Paper End) on pin 12 requires an error-trapping
routine to be included in the Intermec Fingerprint software, acti-
vating the BUSY and READY statements. Here is an example on
how such a routine may be written:
10 IF (PRSTAT AND 4) THEN GOSUB 1000
20 IF (PRSTAT AND 4) = 0 THEN GOSUB 2000
. . . .
. . . .
. . . .
1000 BUSY4
1010 RETURN
2000 READY4
2010 RETURN
Also see BUSY and READY statements and PRSTAT function in
the Intermec Fingerprint v6.14, Reference Manual.
22.3 Connector Confi g-
uration
Pin Signal Dir. Remarks
1 /STROBE In
2 DATA 0 In
3 DATA 1 In
4 DATA 2 In
5 DATA 3 In
6 DATA 4 In
7 DATA 5 In
8 DATA 6 In
9 DATA 7 In
10 ACK Out
11 BUSY Out
12 PE Out See note!
13 SELECT Out
1415 not used
1617 GND
18 + 5V Out If strap fi tted on P-2. Max. 200 mA.
19–30 GND
31 /INPRM In
32 /ERROR Out
33–35 not used
36 /SLCTIN In
37–38 GND Housing
Intermec offers a 3 metres (9.8 ft.) long
ready-made parallel communication
cable (36-p male Centronics DB-
25pin male).
Part No. 1-010001-00

Table of Contents

Related product manuals