89Intermec EasyCoder 501 Service Manual Ed. 7
Chapter 11 Label Taken Sensor
The Label Taken Sensor Kit consists of:
One Re ecting Sensor assy. with cable and connector
One Sensor Bracket
One Screw
One Installation Instructions booklet
The only tools needed are #T10 and #T20 Torx screwdrivers and a
small non-conductive at-tipped screwdriver.
The LTS must either be enabled by means of an LTS& ON state-
ment, or the status of the LTS has to be polled in the Fingerprint
program by means of the PRSTAT function, as otherwise the
printer will not react on the LTS signal.
Make a simple program that checks the printers status, for
example:
10 BREAK 1,88
20 BREAK 1 ON
30 ON BREAK 1 GOSUB 1000
40 FORMFEED
50 IF (PRSTAT AND 2) THEN BEEP
60 GOTO 50
70 END
1000 BREAK 1 OFF
1010 GOTO 70
RUN
You can break this program by transmitting the character
X (ASCII 88 decimal) on the standard serial interface
"uart1:".
Switch off the power. For double security, pull the power cord
out of the receptacle at the rear plate of the printer.
Open the right-hand door and the front hatch, and remove the
left-hand cover.
Press the re ecting sensor assy. into the bracket as illustrated
below.
11.2 Installation
Bracket
Sensor assy.