Chapter 4 — Enabling and Configuring Symbologies
SR60 Scanner Programmer’s Reference Manual 83
Code 128 and UCC/EAN 128 Options
This section describes the Code 128 and UCC/EAN 128 options
and contains the programming bar code labels you can use to
configure those options.
About Code 128 and UCC/EAN 128 Options
The Code 128 and UCC/EAN 128 symbologies have the
following programmable features:
• Minimum Label Length
•Read Verification
Setting Minimum Label Length
Setting Minimum Label Length sets the minimum length
required for Code 128 and UCC/EAN 128 symbology. This
feature causes the scanner to ignore small label segments,
reducing the possibility that a portion of a good label is
incorrectly seen as an entire label.
Read Verification
Read Verification is the number of times the scanner is required
to read the bar code data before sending the label data to the host.
Start/Stop
Don’t Transit ---------
Transmit ---------
END------------------------------------