Translation of original operating instructions 41 of 64
Assembly and installation
sold by Interroll.
Resonance frequencies in the power supply line must be prevented since the create voltage spikes in the motor.
If the cable is too long, frequency inverters generate resonance frequencies in the line between frequency inverter
and motor.
Use a completely shielded cable to connect the frequency inverter to the motor.
Installasine-wavelteroramotorchokeifthecableislongerthan10meterorifafrequencyinvertercontrols
several motors.
Ensure that the cable shield is connected to a grounded part according to the electrotechnical guidelines and local
EMC recommendations.
Always observe the installation guidelines of the frequency inverter manufacturer.