User’s Manual of netMod Network Termination Unit
6. Advice Of Charge During the call (AOC-D)
Using AT commands write on the S89-Register the proper values to allow / restrict the
forwarding of metering pulses on each of netMod’s analogue port (ab1 or ab2).
ATS89=0 deactivates the service on both analogue ports ab1 and ab2.
ATS89=32 deactivates the service on the analogue port ab1 and activates the service on
the analogue port ab2.
ATS89=64 activates the service on the analogue port ab1 and deactivates the service on
the analogue port ab2.
ATS83=96 activates the service on both analogue ports ab1 and ab2.
Using AT commands write on the S89-Register the proper values in order to be informed
through a communication program (e.g. Hyper Terminal) of your PC for the charging on
the analogue ports (ab1 and ab2) and the data port.
ATS89=1 and ATCH? presents the charging of the last outgoing call from the port ab1 and
the total charging.
ATS89=2 and ATCH? presents the charging of the last outgoing call from the port ab2 and
the total charging.
ATS89=4 and ATCH? presents the charging of the last outgoing call from the data port
and the total charging.
ATCH0 resets the charging metering.
Note that this service is initially deactivated in both analogue
ports of netMod.