User’s Manual of netMod Network Termination Unit
Permanent Storage of the S-Registers Settings
The changes in the S-Registers settings are stored in netMod’s RAM memory. This means
that when we restart the system the values in the S-Registers are the factory pre-set
values. To make the storage of the settings permanent, the subscriber has to use the “user
profiles”. The process is described below.
When the desired settings are completed, the user has to give the following commands:
AT&Wn, where n takes the values from 0 to 3, and is the “profile number” where the
settings are stored. This command will store the present settings in the desired “profile”.
To make this “profile” an “active profile” after restarting the system, you have to give the
command:
ATS15= the value that corresponds to the “profile” where we stored the desired
settings.
The settings from the POTS devices keyboard change the values in the S-Registers.
These settings are not permanent. For the storage of these settings, the user profile 0 is
used, and becomes active after resetting.