User’s Manual of netMod Network Termination Unit
0* 0 Enable analogue adapter ab1 incoming calls 0
1 1 Reject analogue adapter ab1 incoming calls
0 * 0 Enable analogue adapter ab2 incoming calls 1
2 2 Reject analogue adapter ab2 incoming calls
dec hex Incoming Call Management
2 4 4 Disable Call Bumping on ab1
3 8 8 Disable Call Bumping on ab2
Bit bin hex
0 0 Normal Operation
1 1 ab1 preferred
10 2 ab2 preferred
4-5
11 3 ab1 and ab2 are ringing alternatively
bit dec hex Layer 2 Deactivation
0 0* 0* Layer 2 will be deactivated on expire of a 10 seconds timer. This
timer starts after the end of the call.
S119=
1 1 Layer 2 will be deactivated only from network side.
dec hex Full Functionality Emergency Mode
0 0 Disables Full Functionality Emergency Mode
S123=
1-
255
1-FF Enables Full Functionality Emergency Mode
Forces analogue ports & the serial port to remain operational if AC
power fails. If this mode is selected, it is possible that the power from
the U-line is not enough. In this case the user must restore the
default value (0).
S124= 0-
255
0-FF Add persist time for BOD in seconds unit
S125= 0-
255
0-FF Sub persist time for BOD in seconds unit
S126= 0-
255
0-FF Add-threshold for BOD in kbps unit
S127= 0-
255
0-FF Sub-threshold for BOD in kbps unit
(*)Default values.
(**)
Some of the signalling monitoring commands may be not available in some software versions of netMod
(***)
Some protocols described in Register S82 may not be available in some software versions of netMod