Invacare®Robin™
Robin™,RobinMover™
enCeilingHoist
ServiceManual..............................3
daLøftemotor
Servicemanual...............................33
frLève-personnesurrail
Manueldemaintenance......................65
itSollevatoreasoffitto
Manualeperlamanutenzione.................99
nlPlafondlift
Servicehandleiding...........................133
no
Takmontertløfter
Servicehåndbok.............................165
svTaklyft
Servicemanual...............................197
DEALER:Keepthismanual.
TheproceduresinthismanualMUSTbeperformedbyaqualifiedtechnician.

Table of Contents

Other manuals for Invacare Robin

Questions and Answers

  • D
    Diane CaseSep 17, 2025
    Why Invacare Personal Care Products lifting straps will only move up and not down?
    • J
      James CochranSep 18, 2025
      If the lifting straps on your Invacare personal care product only move up, the hand control may be defective, and you may need to replace it. Additionally, check if the loose strap function is activated.
  • C
    Cassandra BrownAug 25, 2025
    Why do Invacare Lifting Systems straps only move downwards?
    • S
      Shawn HicksAug 25, 2025
      If your Invacare Lifting Systems hoist straps only move downwards, it could be due to a nearly discharged battery. Try putting the hoist on charge or using the emergency battery. Alternatively, the load might be too high; reduce the load, as the hoist has an over-current safety system. Also, check the hand control, its connection, and the re-entering endstop.
  • R
    rasmussenlouisAug 25, 2025
    What to do if Invacare Lifting Systems hoist hand control is not responding?
    • M
      Monica TurnerAug 26, 2025
      If your Invacare Lifting Systems hoist is not responding correctly to the hand control buttons, but the up/down buttons on the hoist are working, make sure the hand control is securely plugged in. If it is, the hand control may be defective and need to be replaced.
  • R
    robert25Aug 27, 2025
    Why do Invacare Lifting Systems straps only move upwards?
    • C
      Corey PorterAug 27, 2025
      If the Invacare Lifting Systems hoist straps only move upwards, the hand control might be defective and require replacement. Also, check if the loose strap function is activated and, if so, check the loose strap switch.
  • J
    julian80Sep 18, 2025
    Why Invacare Personal Care Products ceiling hoist speed is the same with and without load?
    • R
      Ricky MooreSep 18, 2025
      If the Invacare ceiling hoist maintains the same speed regardless of the load, the non-load quick movement function might be permanently activated; check the quick movement switch. Also, the lifting hooks might not be turning freely enough; try cleaning the hooks or replacing the straps.
  • S
    Susan PhamSep 23, 2025
    What to do if Invacare Mobility Aid ceiling hoist does not respond?
    • J
      Jessica LarsenSep 23, 2025
      If your Invacare Mobility Aid ceiling hoist isn't responding to the hand control buttons or the up/down buttons on the hoist itself, there are a few potential causes: * The emergency stop may be activated: Reset the emergency stop. * The system may not have power or the battery may be discharged: Charge the battery or use the emergency battery. * The fuse may be blown: Replace the fuse.
  • E
    Eric SmithSep 9, 2025
    What to do if no indicator light on Invacare Medical Equipment hoist?
    • D
      dhawkinsSep 9, 2025
      If there is no indicator light on your Invacare Medical Equipment hoist, check that the ceiling hoist has a power supply and that the battery is recharged. Also, place the hand control in the charging station and recharge the ceiling hoist.
  • E
    Emily BowmanSep 10, 2025
    Why Invacare Medical Equipment ceiling hoist does not traverse the rails?
    • J
      jwilsonSep 10, 2025
      If your Invacare Medical Equipment ceiling hoist does not traverse the rails, contact an Invacare representative or specialized dealer for service. The rails may require service or cleaning. Also, if you have a Robin™ model, the trolley might be worn or damaged and need replacement. If you have a Robin Mover™ model, the driving wheels may be worn or damaged and need adjustment, or the hand control might be defective and need replacement.
  • M
    Michael JohnsonSep 3, 2025
    How to fix Invacare Medical Equipment ceiling hoist that will not charge?
    • J
      Jeanette MurphySep 3, 2025
      To address this issue with your Invacare Medical Equipment ceiling hoist, first check that the power supply is switched on and connected to the charging station. If this does not solve the problem, contact an Invacare representative or specialized dealer for service.
  • J
    Jose RhodesSep 1, 2025
    What to do if Invacare Robin Medical Equipment lifting straps will only move down?
    • G
      Gabriel RobinsonSep 1, 2025
      If the lifting straps on your Invacare Medical Equipment only move down and not up, it could be due to a nearly discharged battery. Try charging the battery or using an emergency battery. Another possibility is that the load is too high, as the hoist has an over-current safety system. Try reducing the load.

Summary

General Information

Safety Information

Highlights warnings and cautions for safe operation and maintenance of the hoist.

Service

Installing the Ceiling Hoist to the Rail System

Details the process of installing the Invacare Robin hoist onto the rail system.

Replacing the Hand Control

Detailed steps for replacing the hand control unit of the hoist.

Replacing Strap and Hook Assemblies

Guides on replacing the lifting straps and hook components of the hoist.

Replacing the Battery

Step-by-step instructions for replacing the hoist's battery pack.

Replacing the PCB (Printed Circuit Board)

Detailed procedure for replacing the Printed Circuit Board (PCB) inside the hoist.

Replacing the Fuse

Instructions for safely replacing the fuse in the hoist unit.

Adjusting Loose Strap Switch

Guide on how to adjust the loose strap switch for proper function.

Replacing the Twin Speed Switch

Steps for replacing the twin speed switch component within the hoist.

Replace Contact Disc for Robin Mover

Instructions for replacing the contact disc on Robin Mover hoist models.

Maintenance Procedures

Safety Inspection Checklist

Comprehensive checklist for regular safety inspections of the hoist and rail system.

Troubleshooting Guide

Troubleshooting Table

A table listing common hoist problems and their corresponding solutions.