Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-119-
Current running
command channel
P00.01
Multi-function terminal
36
Switch to keypad
Multi-function
terminal 37
Switch to terminal
Multi-function terminal
38
Switch to
communication
Keypad running
command channel
/
Terminal running
command channel
Communication
running command
channel
Terminal running
command channel
Keypad running
command channel
/
Communication
running command
channel
Communication
running command
channel
Keypad running
command channel
Terminal running
command channel
/
Note: ā€œ/ā€ means the multi-function terminal is invalid on the current reference channel.
Relative parameters table:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.00
Speed
control mode
1: Sensorless vector control mode 1
2: SVPWM control mode
1
P00.01
Running
command
channel
0: Keypad running command channel (LED off)
1: Terminal running command channel (LED flickering)
2: Communication running command channel (LED on)
1
P00.15
Motor
parameter
autotuning
0: No operation
1: Rotation autotuning
2: Static autotuning 1 (autotune totally)
3: Static autotuning 2 (autotune partially)
0
P00.18
Function
restore
parameter
0: No operation
1: Restore the default value
2: Cancel the fault record
0
P02.01
Rated power
of
asynchronous
motor 1
0.1~3000.0kW
Depend
on model
P02.02
Rated
frequency of
0.01Hz~P00.03
(the Max. frequency)
50.00Hz