Goodrive300-19 series open loop vector inverter special for hoist Maintenance and hardware diagnosis
-202-
Maintenance and hardware diagnosis 9
9.1 What this chapter contains
The chapter contains preventive maintenance instructions of the inverter.
9.2 Maintenance intervals
If installed in an appropriate environment, the inverter requires very little maintenance. The table lists
the routine maintenance intervals recommended by INVT.
Check the ambient
temperature, humidity and
vibration and ensure there is
no dust, gas, oil fog or water
drop.
Visual examination
and instrument test
Ensure there are no tools or
other foreign or dangerous
objects.
There are no tools
or dangerous
objects.
Ensure the main circuit and
control circuit are normal.
Ensure the display is clear
enough.
The characters are
displayed normally.
Ensure the characters are
displayed totally.
Ensure the screws are
tightened securely.
Ensure there is no distortion,
crackles, damage or
color-changing caused by
overheat and aging to the
machine.
Ensure there is no dust or
dirtiness
NA
Note: If the color
of copper blocks
changes, it does
not mean there is