Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-133-
P04.30
Voltage
decreasing
time
0.0~3600.0s
5.0s
P04.31
Maximum
output voltage
P04.32~100.0% (the rated voltage of the motor)
100.0%
P04.32
Minimum
output voltage
0.0%~P04.31
0.0%
7.5 Torque control
Goodrive300-19 series inverters support two kinds of control mode: torque control and rotation speed
control. The core of rotation speed is that the whole control focuses on the stable speed and ensures
the setting speed is the same as the actual running speed. The Max. load should be in the range of
the torque limit. The core of torque control is that the whole control focues on the stable torque and
ensures the setting torque is the same as the actual output torque. At the same time, the output
frequency is among the upper limit or the lower limit.