Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-132-
compensation
gain of motor
2
P04.23
Vibration
control factor
at low
frequency of
motor 2
0~100
10
P04.24
Vibration
control factor
at high
frequency of
motor 2
0~100
10
P04.25
Vibration
control
threshold of
motor 2
0.00Hz~P00.03 (the Max. frequency)
30.00Hz
P04.26
Energy-
saving
operation
0: No operation
1: Automatic energy-saving operation
0
P04.27
Voltage
setting
0: Keypad: the output voltage is determined by P04.28.
1: AI1
2: AI2
3: AI3
4: HDI
5: Multi-step speed
6: Reserved
7: Modbus communication
8~10: Reserved
0
P04.28
Keypad
setting
voltage
0.0%~100.0% (the rated voltage of the motor)
100.0%
P04.29
Voltage
increasing
time
0.0~3600.0s
5.0s