EasyManuals Logo

INVT Goodrive300-19 Series User Manual

INVT Goodrive300-19 Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-140-
command
channel
1: Terminal running command channel (LED flickering)
2: Communication running command channel (LED on)
P00.15
Motor
parameter
autotuning
0: No operation
1: Rotation autotuning
2: Static autotuning 1 (autotune totally)
3: Static autotuning 2 (autotune partially)
0
P02.01
Rated power
of
asynchronous
motor 1
0.1~3000.0kW
Depend
on model
P02.02
Rated
frequency of
asynchronous
motor 1
0.01Hz~P00.03
(the Max. frequency)
50.00Hz
P02.03
Rated speed
of
asynchronous
motor 1
1~36000rpm
Depend
on model
P02.04
Rated voltage
of
asynchronous
motor 1
0~1200V
Depend
on model
P02.05
Rated current
of
asynchronous
motor 1
0.8~6000.0A
Depend
on model
P02.06
Stator resistor
of
asynchronous
motor 1
0.001~65.535Ω
Depend
on model
P02.07
Rotor resistor
of
asynchronous
motor 1
0.001~65.535Ω
Depend
on model
P02.08
Leakage
0.1~6553.5mH
Depend

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive300-19 Series and is the answer not in the manual?

INVT Goodrive300-19 Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive300-19 Series
CategoryInverter
LanguageEnglish

Related product manuals