Goodrive300-19 series open loop vector inverter special for hosit Basic operation instruction
-153-
AI1
AI3
HDI
P05.32
P05.33
P05.34
P05.35
P05.42
P05.43
P05.44
P05.45
P05.46
P05.47
P05.50
P05.51
P05.52
P05.53
P05.48
P05.36
P05.54
P17.19
P17.21
P17.22
AI2
P05.37
P05.38
P05.39
P05.40
P05.41
P17.20
P05.00
HDI input type selection
0
1
1
2
0
P05.49
HDI high speed pulse input function selection
AI1 input voltage
AI2 input voltage
AI3 input voltage
HDI input frequency
AI3
AI1/AI2/HDI
P05.00
0: HDI is high speed pulse input
1: HDI is switch input
P05.49
0: frequency setting input
1: counter input
2: length counter input
Analog curve input setting
Analog input filter
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P05.00
HDI input
selection
0: High-speed pulse input
1: Digital input
0
P05.32
Lower limit of
AI1
0.00V~P05.34
0.00V
P05.33
Corresponding
setting of the
lower limit of
AI1
-100.0%~100.0%
0.0%
P05.34
Upper limit of
AI1
P05.32~10.00V
10.00V
P05.35
Corresponding
setting of
the upper limit
of AI1
-100.0%~100.0%
100.0%
P05.36
AI1 input filter
time
0.000s~10.000s
0.100s
P05.37
Lower limit of
0.00V~P05.39
0.00V

Table of Contents