Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-91-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
previous 2
fault
P07.56
Output
terminals
state at
previous 2
fault
0
P08 Group Enhanced function
P08.00
ACC time 2
See P00.11 and P00.12 for detailed definition.
Goodrive300-19 series define four groups of
ACC/DEC time which can be selected by P5 group.
The first group of ACC/DEC time is the factory default
one.
Setting range: 0.0~3600.0s
Depend
on
model
P08.01
DEC time 2
Depend
on
model
P08.02
ACC time 3
Depend
on
model
P08.03
DEC time 3
Depend
on
model
P08.04
ACC time 4
Depend
on
model
P08.05
DEC time 4
Depend
on
model
P08.06
Jogging
frequency
This parameter is used to define the reference
frequency during jogging.
Setting range: 0.00Hz ~P00.03 (the Max. frequency)
5.00Hz
P08.07
Jogging
ACC time
The jogging ACC time means the time needed if the
inverter runs from 0Hz to the Max. frequency.
The jogging DEC time means the time needed if the
inverter goes from the Max. frequency (P0.03) to 0Hz.
Depend
on
model
P08.08
Jogging
Depend