10
Safety and Environment
Safety information
To prevent damage to your product or injury to yourself or to others, read the following safety
precautions in their entirety before using this equipment. Keep this manual in a convenient place so
that you can refer to it when necessary.
Please read carefully all the notices and the warnings of this document because they provide
important information about safety of installation, use and maintenance. Preserve this manual
as future reference.
The installation of the device requires the intervention of qualified staff, adequately trained by
ISEO. The instructions should be carefully followed during installation. The installer must provide
the user with these instructions and / or any other maintenance document.
The product can be destined only for the use for which it was expressly made and, therefore, as
an armored door lock for civil and industrial locations. Any other use is to be considered
improper and dangerous.
Do not work on the door with the lock installed in order to prevent wood or metal residue getting
into the lock.
Distance between striking plate and latch tip, completely in (from both motor or key), must be
between 2 and 3mm.
Handle must not have any friction during the return phase.
Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain
subjected to traction in the rest position. This would compromise infact the latch to be correctly
relased when recalled by key.
Connect the Remote opening command input to 8÷30Vdc/ac power supply source (optoisolated
input).
To use the internal Door status relay (30Vdc/ac - 1A MAX), an external power supply source is
mandatory. Fit therefore a cable gland to allow the relay cable to pass through the hinges side
of the door.
Electrical connections must be done according to the manufacturer’s istructions and in
compliance with the current regulations.
When using a feeder as a direct power supply source (8÷30Vdc/ 30W MAX), fit a cable gland to
allow the cable to pass through the hinge side of the door.
Do not connect the Device to power sources exceeding the indicated ones.
WARNINGS