EasyManuals Logo

Iseo X1R Smart User Manual

Iseo X1R Smart
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
62
Appendix
Events log messages
(Specific for x1RSmart)
Description
Meaning
Close with Mechanical Key
Lock closed by mechanical key.
Configuration changed
The Scheduled Passage Mode has been enabled, disabled or
changed.
Delayed open
Open delayed due to battery in status very low.
Delayed close
Close delayed due to battery in status very low.
Door open
The lock has been opened by any authorized credential (phone,
card, tag or PIN), or by an external command (internal control
module or remote opening command).
Door Close
Door closed, x1R bolts automatically close. Maximum security.
Door Close Light
Door closed with Light Mode enabled. Only latch in, bolts not out.
Functional Mode change
The functional mode Outside Knob/Outside Handle has changed.
This function is only available on x1R Smart Standard.
Lock bolts in half-way by handle
Lock bolts in half-way by handle
Lock bolts in half-way by key
Bolts have been moved by key but not completely in. Just 1 shot
(half-way).
Lock not close due to motor
extra-current error
It happens when there is an excessive friction of latch or bolts
during closing.
Lock not close due to sensor
time-out error
It may happen when motor does not engage the mechanic during
closing.
Lock not open due to motor
extra-current error
It happens when there is an excessive friction of latch or bolts
during opening.
Lock not open due to sensor
time-out error
It may happen when motor does not engage the mechanic during
opening.
Open with Internal Handle
Lock opened from the inside by the internal handle.
Open with Mechanical Key
Lock opened by mechanical key.
Open by remote opening button
Lock opened by remote opening button.
Open denied due to internal handle
pressed
It happens when, opening by any electrical command, the internal
handle is slightly down enough to activate its internal sensor. It
may happen for example in case of x1R combined with panic bar
device, if installation has not been correctly done the weight of the
bar could cause this issue.

Other manuals for Iseo X1R Smart

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Iseo X1R Smart and is the answer not in the manual?

Iseo X1R Smart Specifications

General IconGeneral
BrandIseo
ModelX1R Smart
CategoryLocks
LanguageEnglish

Related product manuals