43
Advanced settings menu
Inside the Door Info menu, tap Advanced Settings. You will see the following editable parameters.
It is the time that allows user to open the door
following an opening command. If the door is not
opened during this time, it will automatically lock.
You can disable or enable all x1R Smart sounds. If
disabled the lock will not emit any sound.
If this function is enabled, a lock already set in
Passage Mode, following a power OFF, will restore
automatically the Passage Mode function when ON again.
For more information, refer to the Argo User Manual
at link: https://app.iseo.com
This parameter shows the type of lock: Single Action or
Standard. See detailed information in the related paragraph.
You can set the Passage Mode in Light or Free. See
detailed information in the related paragraph.
it is the elapsing time between the door closing action
and the bolts physical movement starts.
It allows you to differently configure the internal relay
behavior. To know more about this function go to
Door status relay paragraph.
You can choose if restore the default doorlock
settings or make a total reset of the lock as received
from the factory.
It allows you to enable or disable the internal control
module opening and closing buttons and the remote
opening command, if present.
It’s Yes when the lock is used with a 3
rd
party app
(OEM = Original Equipment Manufacturer).