15
Classification digits explanation:
EN 179:2008
Digits
1
2
3
4
5
6
7
8
9
10
x1R 699SA
3
7
7
B
1
4
5
2
A
B
Digits
Description
Classification
1
Category of Use
3 = for use by the public where there is little
incentive to exercise care and where there is a
high chance of misuse.
2
Durability
7 = 200.000 test cycles - 120N load on latch bolt.
3
Door Mass
7 = above 200 kg door mass as specified by the
manufacturer.
4
Suitability on use on fire/smoke doors
B = suitable for use on smoke and fire door
assemblies.
5
Safety
1 = all panic exit devices have a critical safety
function, only the top grade is identified for the
purpose of EN179:08.
6
Corrosion resistance and temperature
4 = very high corrosion resistance (240h);
temperature requirement: from 10 °C to +60 °C
7
Security
5 = 5000 N
8
Projection of the operating element
2 = projection up to 100 mm (standard projection).
9
Type of operation
A = emergency exit device with "lever handle"
operation.
10
Field of door application
B = outwardly opening single exit door only.
Safety and Environment

Other manuals for Iseo X1R Smart

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Iseo X1R Smart and is the answer not in the manual?

Iseo X1R Smart Specifications

General IconGeneral
BrandIseo
ModelX1R Smart
CategoryLocks
LanguageEnglish

Related product manuals