Chapter 11 SETUP MODE
11.9 DEFAULT DATA SETTING
1.
Press the “Default Data” field on the Setup Menu Select screen.
2.
The Item Initial Data (Sales 1) screen appears.
ITEM DESCRIPTION
Press the [<] or [>] button to select a desired Sales Mode.
SALES MODE
0: Weighing product
1: Fixed price product
2: Weighing fixed price product
3: Fixed unit price
Press the [<] or [>] button to select a desired Markdown Mode.
MARKDOWN
MODE
1: Special price
2: Amount discount for total price
3: Percent discount for total price
4: Special unit price
5: Amount discount for unit price
6: Percent discount for unit price
Uni-7 User’s Manual 11-21

Table of Contents

Other manuals for ISHIDA UNI-7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA UNI-7 and is the answer not in the manual?

ISHIDA UNI-7 Specifications

General IconGeneral
Use conditionsTemperature: -5 to 35°C Humidity: 30 to 85%, Non condensing.
Power supply:AC100 – 240V, 50 / 60Hz
Power consumption1.0A/0.5A
Weighing capacity Scale interval15 kg: 0 to 6/0.002 kg, 6 to 15/0.005 kg 30 lb: 0 to 15/0.005 lb, 15 to 30/0.01 lb
Weighting accuracy1/3000
Printing methodDirect thermal method
Printing speed100mm/second, 120mm/second Note: The printing speed may vary according to label conditions.
Printing effective size56mm
Label sizeLabel width: 30mm to 60mm Label length: 20mm to 150mm
Operator/Customer display7.0 inch color liquid crystal with back light, 480 X 234dots
Thermal head2 inches (448dots) and 8 dots/mm
Number of label cassettes7 cassettes
Program store mediumFlash ROM (32M bytes)
Input/OutputLAN 1 channel USB 1 channel CF 1 channel Drawer 2 channels