EasyManuals Logo

ISHIDA UNI-7 User Manual

ISHIDA UNI-7
309 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Chapter 2 LABEL ISSUE
With Preset Tare Weight
Manual Tare Entry
To newly enter a tare weight or overwrite an existing tare weight, enter the tare weight
using the numeric keys and press the “TARE” field on the screen.
EXAMPLE Tare weight “50g”
5.
See Chapter 5 for more details about temporary change operations.
6.
Put a product on the weigh platter.
The weight is measured but the fixed price stays same.
Uni-7 User’s Manual 2-5

Table of Contents

Other manuals for ISHIDA UNI-7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA UNI-7 and is the answer not in the manual?

ISHIDA UNI-7 Specifications

General IconGeneral
Use conditionsTemperature: -5 to 35°C Humidity: 30 to 85%, Non condensing.
Power supply:AC100 – 240V, 50 / 60Hz
Power consumption1.0A/0.5A
Weighing capacity Scale interval15 kg: 0 to 6/0.002 kg, 6 to 15/0.005 kg 30 lb: 0 to 15/0.005 lb, 15 to 30/0.01 lb
Weighting accuracy1/3000
Printing methodDirect thermal method
Printing speed100mm/second, 120mm/second Note: The printing speed may vary according to label conditions.
Printing effective size56mm
Label sizeLabel width: 30mm to 60mm Label length: 20mm to 150mm
Operator/Customer display7.0 inch color liquid crystal with back light, 480 X 234dots
Thermal head2 inches (448dots) and 8 dots/mm
Number of label cassettes7 cassettes
Program store mediumFlash ROM (32M bytes)
Input/OutputLAN 1 channel USB 1 channel CF 1 channel Drawer 2 channels