[Error content] There was no response from the applicator
[Detail]
・Unable to communicate between the console and applicator.
・Communication phase number is in the sub-error.
・Communication errors during power ON result in this error.
[Solution]
[OK]
-> Cut communication with the applicator. Operate without the
applicator.
[RETRY]
-> Check connection with the applicator. The error is cleared if
connection can be confirmed.
[Remarks]
It is possible to operate without the applicator after pressing the [OK]
button.
[Cause] P-910<-P-918<-P-916 (No response from P-916)
[Response] Press the [RETRY] key and attempt communication. The consider the
following causes if the error re-occurs:
1)Unplugged connector
2)Shorted harness
3)Board P-910 malfunction
4)Board P-918 malfunction
5)Board P-916 malfunction
• The problem may also occur if there is a closed-circuit failure in
the P-915 and P-920 RS-485 line. Check this if the problem is
not solved by 1 through 5.
• Connect boards P-915, P-916, and P-920 one at a time to
search for the board closed-circuit failure.
Confirm with a drawing