Page #27 background image
[Error content] There was no response from the applicator
[Detail]
・Unable to communicate between the console and applicator.
・Communication phase number is in the sub-error.
・Communication errors during power ON result in this error.
[Solution]
[OK]
  -> Cut communication with the applicator. Operate without the
applicator.
[RETRY]
  -> Check connection with the applicator. The error is cleared if
connection can be confirmed.
[Remarks]
It is possible to operate without the applicator after pressing the [OK]
button.
[Cause] P-910<-P-918<-P-916 (No response from P-916)
[Response] Press the [RETRY] key and attempt communication. The consider the
following causes if the error re-occurs:
1)Unplugged connector
2)Shorted harness
3)Board P-910 malfunction
4)Board P-918 malfunction
5)Board P-916 malfunction
The problem may also occur if there is a closed-circuit failure in
the P-915 and P-920 RS-485 line. Check this if the problem is
not solved by 1 through 5.
Connect boards P-915, P-916, and P-920 one at a time to
search for the board closed-circuit failure.
Confirm with a drawing
0650
Ishida WM-4000 Error Codes and Solutions (600-2099)
March 2015
26/84

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA WM-4000 and is the answer not in the manual?

ISHIDA WM-4000 Specifications

General IconGeneral
BrandISHIDA
ModelWM-4000
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals