EasyManua.ls Logo

ISHIDA WM-4000 - 1601

ISHIDA WM-4000
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
[Error content] Scale span adjustment incomplete.
[Detail] The response from the scale is included in the sub-error.
[Solution] [OK] button
[Remarks] Need to re-set the span.
[Cause] Scale (P-930) span adjustment incomplete.
[Response]
1. Perform spring span.
2. If the same error occurs, replace board P-930.
1601
Ishida WM-4000 Error Codes and Solutions (600-2099)
March 2015
66/84

Related product manuals