[Error content] Scale initialization has not been completed.
[Detail] The response from the scale is included in the sub-error.
[Solution] [OK] button
[Remarks] Need to re-set span.
[Cause] Scale (P-930) initialization has not been completed.
[Response]
1. Perform spring span.
2. If the same error occurs, replace board P-930.