[Error content]
Tray detector power failure or the tray detector board CPU was
reset.
[Detail]
A different command was received before the power ON
communication command.
[Solution] Restore power
[Remarks]
[Cause]
Tray detector (P-915) power failure or the tray detector board CPU
was reset.
[Response]
1. Restore power.
2. If the same error occurs, check P-915 (XJ-7) voltage DC 24V.
3. If the power supply voltage is normal, replace P-915.
1505
Ishida WM-4000 Error Codes and Solutions (600-2099)