[Error content] Power failure detected in the applicator
[Detail] Power ON notification command was received twice from the console.
[Solution] Restore power
[Remarks]
[Cause] P-910 board was reset twice
[Response]
Restore power. If the same error occurs, consider the following
causes:
1)Input power (AC 200V) to power unit (U220) is unstable
2)Check power unit (U220) output voltage (DC 24V)
0604
Ishida WM-4000 Error Codes and Solutions (600-2099)