System Commands
Copyright © Itech Electronic Co., Ltd. 13
mode(control from panel). In this mode ,all of keys on front panel is valid.
Command syntax
SYST:LOC
Parameters
None
Query syntax
None
SYSTem:RWLock
This command is transmit through interface, the same function as
SYST:REM, but the difference is: this command can lock “LOCAL” button
as well. When this command is executed, the “Local” button can’t switch
to local control mode.
Command syntax
SYST:RWL
SYSTem:BEEPer
This command is used to turn on/turn off the beeper, when the arguments is set
to 1/ON, the beeper is enabled and press keyboard will beeper, otherwise, it is
mute.
Command syntax
SYSTem:BEEPer
Parameters
OFF|ON|0|1
Example
SYST:BEEP 1
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess
This command is used to set the address of GPIB interface.
IT7321 instrument has no GPIB interface, so the command is only applicable to
other models.
Command syntax
SYSTem:COMMunicate:GPIB:RDEVice:ADDRess <NR1>

Table of Contents

Other manuals for ITech IT7321

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT7321 and is the answer not in the manual?

ITech IT7321 Specifications

General IconGeneral
BrandITech
ModelIT7321
CategoryPower Supply
LanguageEnglish

Related product manuals