IEEE488.2 Common Commands
Copyright © Itech Electronic Co., Ltd. 58
command, the value of bit6 in status byte register will be clean.
Query syntax
*STB?
Parameters
None
Returns
<NR1>
Related commands
*CLS *ESE *ESR
*TRG
When the trigger mode of the power supply is BUS order trigger mode, the
order will Generates a trigger signal. The function is the same as
TRIGger[:IMMediate]
Command syntax
*TRG
Parameters
None
Related commands
TRIG TRIG:SOUR
*SAV
This command will save the current setting value of the power supply to the
specified storage area. These parameters include: set voltage, set frequency,
start phase, stop phase, output gear and Dimmer phase angle.
Command syntax
*SAV<NRf>
Parameters
0~9
Example
*SAV 3