EasyManua.ls Logo

ITech IT7321 - Config:protect:current:rms:mode; Config:protect:current:peak; Config:protect:current:peak:mode

ITech IT7321
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration Commands
Copyright © Itech Electronic Co., Ltd. 21
CONFig:PROTect:CURRent:RMS:MODe
This command is used to set current rms protection mode: DELay|IMMediate.
Command syntax
CONFig:PROTect:CURRent:RMS:MODe
Parameters
DELay|IMMediate
Delay: Enable protection after 1s delay.
IMMediate: Turn on protection now.
Example
conf:prot:curr:rms:mod del
Query syntax
CONFig:PROTect:CURRent:RMS:MODe?
CONFig:PROTect:CURRent:PEAK
This command is used to configure the current peak protection point. The
command function is equivalent to Ipeak-Protect in the instrument panel menu.
Command syntax
CONFig:PROTect:CURRent:PEAK
Parameters
MINimum|MAXimum|Float
Example
conf:prot:curr:peak 3
Query syntax
CONFig:PROTect:CURRent:PEAK?
CONFig:PROTect:CURRent:PEAK:MODe
This command is used to set current peak protection mode: DELay|IMMediate.
Command syntax
CONFig:PROTect:CURRent:PEAK:MODe
Parameters
DELay|IMMediate
Delay: Enable protection after 1s delay.
IMMediate: Turn on protection now.

Table of Contents

Other manuals for ITech IT7321