Basic Operation
Analog quantity menu description
When the analog quantity function is optionally equipped, the system menu dis-
plays the analog quantity menu. The analog quantity menu items and parame-
ters are described below:
Ext-Program External analog function menu
On / Off Function switch:
• On: Turns on the external analog function.
In this state, the channel parameters cannot
be set.
• Off: Turns off the external analog function.
In this state, the channel parameters can be
set.
CV Calculation parameter setting of the setting val-
ue in CV mode.
M Slope coefficient set by voltage.
b Offset set by voltage.
CC Calculation parameter setting of the setting val-
ue in CC mode.
M Slope coefficient set by current.
b Offset set by current.
CP Calculation parameter setting of the setting val-
ue in CP mode.
M Slope coefficient set by power.
b Offset set by power.
CR Calculation parameter setting of the setting val-
ue in CR mode.
M Slope coefficient set by resistance.
b Offset set by resistance.
Analog Conversion Relationship Introduction
When the analog quantity control function of this series of instrument is used,
the user needs to set the conversion relationship of the analog quantity ex-
pected value based on requirements. The analog quantity values in each mode
Copyright © Itech Electronic Co., Ltd.
100