Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 61
Model IT8924-1200-480
Rated value
(0
40
)
operating
0.58V/48A 5.8V/480A
Constant
voltage
mode
Range 0.1~120V 0.1~1200V
Resolution 10mV 100mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant
current
mode
Range 0~48A 0~480A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Constant
resistance
mode *1
Accuracy
0.01%+0.08S
0.01%+0.0008S
Constant power
Mode *3
Measuring range
Read-back
voltage
Range 0~120V 0~1200V
Resolution 10mV 100mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~48A 0~480A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Read-back
power
Range 24KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
≒24.2KW
≒52.8A ≒528A
≒1250V
Overtemperatur
e protection
≒85℃
Short circuit
Current (CC)
≒52.8A ≒528A
Voltage (CV) 0V 0V
Resistance (CR)
≒12mΩ ≒12mΩ
≒2MΩ
2
U
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).