EasyManua.ls Logo

ITech IT8900 Series - Page 73

ITech IT8900 Series
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 64
Model IT8930-1200-600
Rated value
(0
40
)
Input voltage
0~1200V
Input current
0~60A
0~600A
Input power
30KW
Min. operating
voltage
0.6V/60A 6V/600A
Constant voltage
mode
Range 0.1~120V 0.1~1200V
Resolution 10mV 100mV
Accuracy
±(0.05%+0.05%FS)
±(0.05%+0.05%FS)
Constant current
mode
Range 0~60A 0~600A
Resolution 1mA 10mA
Accuracy ±(0.1%+0.1%FS) ±(0.1%+0.1%FS)
Constant
resistance mode
*1
Range
0.02Ω~10Ω
10Ω~7.5KΩ
Resolution
16bit
Accuracy
0.01%+0.08S *2
0.01%+0.0008S
Constant power
Mode *3
Range
30KW
Resolution
1W
Accuracy
0.2%+0.3%FS
Measuring range
Read-back voltage
Range 0~120V 0~1200V
Resolution 10mV 100mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back current
Range 0~60A 0~600A
Resolution 1mA 10mA
Accuracy ±(0.1%+0.1%FS) ±(0.1%+0.1%FS)
Read-back power
Range 30KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
Overpower
protection
30.3KW
Overcurrent
protection
66A 660A
Overvoltage
protection
1250V
Overtemperature
protection
85
Specification
Short circuit
Current (CC)
66A 660A
Voltage (CV) 0V 0V
Resistance (CR)
10mΩ 10mΩ
Input terminal
impedance
2MΩ
Dimension
37U
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.

Table of Contents