Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 65
Model IT8936-600-1440
Rated value
(0
40
)
Input voltage
0~600V
Input current
0~144A
0~1440A
Input power
36KW
Min. operating
voltage
0.44V/144A 4.4V/1440A
Constant voltage
mode
Range 0.1~60V 0.1~600V
Resolution 1mV 10mV
Accuracy
±(0.05%+0.05%FS)
±(0.05%+0.05%FS)
Constant current
mode
Range 0~144A 0~1440A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.1%FS)
Constant
resistance mode
*1
Range
0.005Ω~10Ω
10Ω~7.5KΩ
Resolution
16bit
Accuracy
0.01%+0.08S *2
0.01%+0.0008S
Constant power
Mode *3
Range
36KW
Resolution
1W
Accuracy
0.2%+0.3%FS
Measuring range
Read-back voltage
Range 0~60V 0~600V
Resolution 1mV 10mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back current
Range 0~144A 0~1440A
Resolution 10mA 100mA
Accuracy ±(0.1%+0.1%FS) ±(0.2%+0.1%FS)
Read-back power
Range 36KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
Overpower
protection
36.3KW
Overcurrent
protection
158A 1580A
Overvoltage
protection
630V
Overtemperature
protection
85
Specification
Short circuit
Current (CC)
158A 1580A
Voltage (CV) 0V 0V
Resistance (CR)
3mΩ 3mΩ
Input terminal
impedance
1MΩ
Dimension
37U
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.