Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 66
Model IT8936-1200-720
Rated value
(0
~
40
℃
)
Input voltage
0~1200V
Input current
0~72A
0~720A
Input power
36KW
Min. operating
voltage
0.58V/72A 5.8V/720A
Constant voltage
mode
Range 0.1~120V 0.1~1200V
Resolution 10mV 100mV
Accuracy
±(0.05%+0.05%FS)
±(0.05%+0.05%FS)
Constant current
mode
Range 0~72A 0~720A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Constant
resistance mode
*1
Range
0.01Ω~10Ω
10Ω~7.5KΩ
Resolution
16bit
Accuracy
0.01%+0.08S *2
0.01%+0.0008S
Constant power
Mode *3
Range
36KW
Resolution
1W
Accuracy
0.2%+0.3%FS
Measuring range
Read-back voltage
Range 0~120V 0~1200V
Resolution 10mV 100mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back current
Range 0~72A 0~720A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Read-back power
Range 36KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
Overpower
protection
≒36.3KW
Overcurrent
protection
≒75A ≒750A
Overvoltage
protection
≒1250V
Overtemperature
protection
≒85℃
Specification
Short circuit
Current (CC)
≒75A ≒750A
Voltage (CV) 0V 0V
Resistance (CR)
≒8mΩ ≒8mΩ
Input terminal
impedance
≒2MΩ
Dimension
37U
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.