Technical Specifications
Copyright © ITECH Electronic Co., Ltd. 70
Model IT8948-1200-960
Rated value
(0
40
)
0.67V/96A 6.7V/960A
Constant voltage
mode
Range 0.1~120V 0.1~1200V
Resolution 10mV 100mV
Accuracy ±(0.05%+0.05%FS) ±(0.05%+0.05%FS)
Constant current
mode
Range 0~96A 0~960A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Constant
resistance mode
*1
Constant power
Mode *3
Range 48KW
Resolution 1W
Measuring range
Read-back
voltage
Range 0~120V 0~1200V
Resolution 10mV 100mV
Accuracy ±(0.025%+0.025%FS) ±(0.025%+0.025%FS)
Read-back
current
Range 0~96A 0~960A
Resolution 1mA 10mA
Accuracy ±(0.05%+0.1%FS) ±(0.1%+0.1%FS)
Read-back power
*2
Range 48KW
Resolution 1W
Accuracy ±(0.2%+0.3%FS)
Protection range
≒48.4KW
≒96A ≒960A
≒1250V
Overtemperature
protection
≒85℃
Short circuit
Current (CC)
≒105A ≒1050A
Voltage (CV) 0V 0V
Resistance
(CR)
≒7mΩ ≒7mΩ
≒2MΩ
27U*2
*1.The voltage/current input is no less than 10%FS (FS indicates the full
scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).